SLA & Uptime Calculator: 99.9% Downtime Allowed
Downtime an SLA allows per month and year, the SLA a downtime means, and the combined SLA of components.
- Downtime per day
- 1 min 26 s
- Per week
- 10 min 5 s
- Per quarter
- 2 h 11 min 24 s
- Per year in minutes
- 525.6 min
Formula and sources
Allowed downtime = (1 − SLA) × period; 1 year = 365 days, 1 month = 1/12 year (30.42 days), 1 quarter = 1/4 year SLA from downtime = 1 − downtime ÷ period Combined: components in series multiply; a component with n independent copies = 1 − (1 − SLA)^n
When to use the SLA & Uptime
What the nines mean
A 99.9% SLA allows about 43 minutes of downtime a month or 8 hours 45 minutes a year. 99.99% allows only 4 minutes 23 seconds a month. Each extra nine cuts the downtime to a tenth.
From an outage to a percentage
The second mode turns a downtime into a percentage: 90 minutes of outage in a month is 99.79%. Compare it with the contract SLA to see whether the provider kept its promise.
A combined SLA is always lower
When a service needs the internet link, firewall, server and database all at once, its SLA is the product of them all, lower than the weakest part. Two 99.9% components in a row give only about 99.8%.
Redundancy raises it
Two independent copies fail only if both are down together. Two 99.5% internet links become 99.9975%. Enter the number of copies on redundant components to see the effect.
Frequently asked questions
How much downtime does 99.5% allow?
About 3 hours 39 minutes a month, or 1 day 19 hours 48 minutes a year. That is roomy for an internal service but a lot for a customer-facing one.
Does planned maintenance count?
It depends on the contract. Many SLAs exclude maintenance windows announced in advance, so read how your agreement defines and measures downtime before you calculate.
Why is a month 30.42 days?
The calculator uses the average 365 days ÷ 12 so every month is the same. An SLA measured per calendar month differs slightly for February or 31-day months.