PoE Cable Voltage Drop Calculator
Calculate PoE Cat6, Cat5e, and CCA cable voltage drop, delivered terminal voltage, safe run distances, and night-time infrared reboot risks.
Input Parameters
Calculation Results
- UTP Cable Run Length
- 65 Meters
- UTP Cable Type & Conductor
- cat6
- PoE Powered Device (PD) Load
- 8 Watts
- PoE Switch Source Voltage (PSE)
- 48 Volts
- DC Loop Resistance per 100m
- 14 Ω
- Total Cable Loop Resistance
- 9.1 Ω
- PoE Line Current
- 0.167 Amperes
- Cable Voltage Drop
- 1.52 Volts
- Voltage Delivered at Camera (PD)
- 46.48 Volts
- Voltage Drop Percentage
- 3.2 %
- Power Loss Dissipated in Cable
- 0.25 Watts
- PoE Voltage Delivery Status
- SAFE (Complies with IEEE 802.3af/at)
- Field Diagnostic Note
- Voltage delivered at device endpoint is highly stable.
Use 24/7 CMR surveillance drives in NVRs and solid bare copper Cat6 for PoE runs exceeding 50 meters.
Ringkasan Jatuh Tegangan (Voltage Drop) Kabel PoE – InfraCalc.web.id Tipe Kabel : CAT6 (Hambatan Loop: 14 Ω / 100m) Panjang Tarikan : 65 meter (Total Hambatan: 9.1 Ω) Daya Beban : 8 Watt @ Sumber 48V DC (Arus: 0.1667 A) Voltage Drop : 1.52 V (3.2%) Tegangan Ujung : 46.48 V DC (Rugi Daya: 0.25 W) Status Kelayakan: AMAN (Standar IEEE 802.3af/at) Rekomendasi : Tegangan di ujung kamera sangat stabil.
Technical Accuracy Note: Calculation results are engineering estimates based on standard RFC/IEEE/ITU-T models. Actual field performance may vary due to protocol overhead, hardware specifications, and environmental factors.
How to Use This Tool
- Enter the physical cable run length from the PoE switch to the camera endpoint in meters.
- Select the cable conductor category (Cat6 Pure Copper, Cat5e Pure Copper, or Copper-Clad Aluminum CCA).
- Specify maximum camera power consumption with IR illuminated (Watts) and review delivered terminal voltage.
Worked Example: Standard 65m Cat6 Run 8W Camera
Worked example: A 65m CAT6 cable run for an 8W device powered from a 48V PSE yields a loop resistance of 9.1 Ω and a voltage drop of 1.52V (3.2%). Delivered terminal voltage is 46.48V DC (Status: SAFE (Complies with IEEE 802.3af/at)).
- Cable Run Length
- 65 Meters
- Cable Conductor Type
- Cat6 Pure Bare Copper (~14.0 Ω/100m)
- Device Load Power (Watts)
- 8 Watts
- PoE Switch Source Voltage
- 48V DC (Standard IEEE 802.3af/at Nominal)
- UTP Cable Run Length
- 65 Meters
- UTP Cable Type & Conductor
- cat6
- PoE Powered Device (PD) Load
- 8 Watts
- PoE Switch Source Voltage (PSE)
- 48 Volts
- DC Loop Resistance per 100m
- 14 Ω
- Total Cable Loop Resistance
- 9.1 Ω
- PoE Line Current
- 0.167 Amperes
- Cable Voltage Drop
- 1.52 Volts
- Voltage Delivered at Camera (PD)
- 46.48 Volts
- Voltage Drop Percentage
- 3.2 %
- Power Loss Dissipated in Cable
- 0.25 Watts
- PoE Voltage Delivery Status
- SAFE (Complies with IEEE 802.3af/at)
- Field Diagnostic Note
- Voltage delivered at device endpoint is highly stable.
- Material Requirement Summary (Copy-Ready)
- Ringkasan Jatuh Tegangan (Voltage Drop) Kabel PoE – InfraCalc.web.id Tipe Kabel : CAT6 (Hambatan Loop: 14 Ω / 100m) Panjang Tarikan : 65 meter (Total Hambatan: 9.1 Ω) Daya Beban : 8 Watt @ Sumber 48V DC (Arus: 0.1667 A) Voltage Drop : 1.52 V (3.2%) Tegangan Ujung : 46.48 V DC (Rugi Daya: 0.25 W) Status Kelayakan: AMAN (Standar IEEE 802.3af/at) Rekomendasi : Tegangan di ujung kamera sangat stabil.
Core Concept & Engineering Notes
How It Was Calculated (Formulas & Steps)
Mathematical Formulas
- Total Loop Resistance (Ω) = (Resistance per 100m × Run Length m) ÷ 100
- Electrical Current (A) = Load Power Watts ÷ Source Voltage DC
- Voltage Drop (V) = Current A × Total Resistance Ω
- Terminal Endpoint Voltage (V) = Source Voltage - Voltage Drop
- Percentage Drop (%) = (Voltage Drop ÷ Source Voltage) × 100
- Thermal Power Dissipation (W) = Voltage Drop × Current A
Step-by-Step Calculation
- 1. Loop Resistance: CAT6 wire = 14 Ω / 100m -> R_total = (14 × 65) / 100 = 9.1 Ω
- 2. Load Current: I = P / V_source = 8 W / 48 V = 0.1667 A
- 3. Voltage Drop: V_drop = I × R_total = 0.1667 A × 9.1 Ω = 1.52 V (3.2% loss)
- 4. Endpoint Voltage Delivered: V_end = 48 V - 1.52 V = 46.48 V DC (Heat Dissipation = 0.25 W)
- 5. Compliance Assessment: SAFE (Complies with IEEE 802.3af/at). Recommendation: Voltage delivered at device endpoint is highly stable.
Frequently Asked Questions (FAQ)
Why do PoE CCTV cameras frequently reboot or drop offline specifically at night?
Nightfall triggers automatic infrared (IR) illuminators, surging camera power consumption 2 to 3 times higher. This elevated current doubles the voltage drop along the cable. On lengthy runs or sub-standard CCA cables, endpoint voltage drops below the camera's operational floor, triggering continuous reboot loops.
What is the maximum UTP cable distance for standard PoE without repeaters?
IEEE 802.3 Ethernet standards limit copper cable runs to 100 meters. Spans between 100m and 250m require toggling 'Extend Mode' on the PoE switch (throttling bandwidth to 10 Mbps) with solid Cat6 pure copper. Any distance beyond 250 meters mandates single-mode fiber optic cable.
What are the engineering hazards of using Copper-Clad Aluminum (CCA) cables?
CCA conductors feature a brittle aluminum core that easily fractures under pull tension and suffers over double the electrical resistance of pure copper. In addition to severe voltage drops, CCA cables generate dangerous resistive thermal heating when carrying higher PoE current loads, posing longevity and safety risks.
Related Calculators
View All CCTV, PoE & Fiber Tools →Calculate CCTV lens focal length recommendations (2.8mm, 4mm, 6mm, 12mm), field of view coverage width, and DORI pixel density per target distance.
Estimate CCTV installation material Bill of Materials (BOM): Cat6 UTP cable boxes, RJ45 modular plugs, junction boxes, conduit pipes, and cable ties.
Calculate CCTV camera, NVR, and PoE switch UPS apparent power (VA) and deep-cycle VRLA battery capacity (Ah) for power outage runtime.
Calculate EN 62676-4 CCTV DORI detection, observation, recognition, and facial identification reach distances based on sensor resolution and lens optics.
Calculate CCTV NVR storage capacity (TB), network ingress bandwidth Mbps, recording retention days, PoE budgets, and surveillance HDD recommendations.
Interactive 2D floorplan planner for estimating Wi-Fi AP 2.4/5GHz signal coverage radii and CCTV camera FoV DORI coverage cones visually.
References & Notes
- IEEE 802.3af-2003 / 802.3at-2009 Standards for Power over Ethernet
- ANSI/TIA-568.2-D Balanced Twisted-Pair Telecommunications Cabling and Components Standard
- Hikvision CCTV Cabling Distance and PoE Long Range Deployment Guide
Note: Results above are mathematical estimates based on standard formulas. Always verify against official vendor documentation and site conditions before production deployment.
🔗Related Scenarios & Companion Calculators
Browse All 30+ Scenarios →⚡ Ready-to-Use Scenario Presets:
How much HDD storage do 16 1080p CCTV cameras need for 30 days 24/7? Compare H.265 (~4.2 TB) vs H.264 (~8.4 TB) NVR requirements.
Calculate exact HDD size for 8 CCTV cameras recording 30 days 24/7. Requires ~2.1 TB with H.265 (use a 4 TB HDD).
🛠️ Sibling Calculators in this Category:
Calculate CCTV lens focal length recommendations (2.8mm, 4mm, 6mm, 12mm), field of view coverage width, and DORI pixel density per target distance.
Calculate EN 62676-4 CCTV DORI detection, observation, recognition, and facial identification reach distances based on sensor resolution and lens optics.
Calculate CCTV NVR storage capacity (TB), network ingress bandwidth Mbps, recording retention days, PoE budgets, and surveillance HDD recommendations.
Estimate CCTV installation material Bill of Materials (BOM): Cat6 UTP cable boxes, RJ45 modular plugs, junction boxes, conduit pipes, and cable ties.
Engineering Sensitivity Analysis, Response Curve & Technical Citation
1. 1. 3-Point Engineering Sensitivity & Tolerance Envelope
Comparative evaluation across theoretical laboratory bounds (0% loss), current nominal operating point, and conservative field safety bounds (±15% thermal/aging derating).
| Evaluated Parameter | Ideal Theoretical Bound | Nominal Operating Point | Conservative Safety Bound (±15%) | Engineering Derating Rule |
|---|---|---|---|---|
| UTP Cable Run Length | 58.5 | 65 | 74.75 | Engineering Safety Margin (+15% Overhead) |
| PoE Powered Device (PD) Load | 7.2 | 8 | 9.2 | Engineering Safety Margin (+15% Overhead) |
| PoE Switch Source Voltage (PSE) | 43.2 | 48 | 55.2 | Engineering Safety Margin (+15% Overhead) |
| DC Loop Resistance per 100m | 12.6 | 14 | 16.1 | Engineering Safety Margin (+15% Overhead) |
| Total Cable Loop Resistance | 8.19 | 9.1 | 10.46 | Engineering Safety Margin (+15% Overhead) |
2. 2. Mathematical Function Curve & Operating Coordinate (x₀, y₀)
3. 3. Physical Constants & Normative Standard Clauses
Minimum Horizontal Pixel Density for Identification (DORI)
Clause 6.5 & Table A.1 (25 / 62 / 125 / 250 px/m) — Video surveillance standard specifies Detection=25 px/m, Observation=62 px/m, Recognition=125 px/m, Identification=250 px/m.
DC Loop Resistance for 23 AWG Solid Copper Cat6
Clause 6.4.1 / Table 145-1 — Nominal 23 AWG solid copper loop resistance at 20°C is 14.0 Ω/100m (TIA maximum ceiling is 18.8 Ω/100m).
Temperature Coefficient of Resistance for Copper
International Annealed Copper Standard — Used in thermal derating equation: R(T) = R_20 × [1 + 0.00393 × (T - 20)].
4. 4. Independent Technical & Academic Citation (IEEE / APA 7th / BibTeX / LaTeX)
Use the standard citation formats below to reference this computational methodology in engineering specifications, audit reports, or academic papers.
[IEEE] KalkuNet Engineering Team, "PoE Cable Voltage Drop Calculator — Standard Engineering Computational Instrument," KalkuNet Technical Suite, 2026. [Online]. Available: https://kalkunet.com/en/tools/poe-voltage-drop-calculator. [Accessed: 2026-11-08].
[APA 7th] KalkuNet Engineering Team. (2026). PoE Cable Voltage Drop Calculator (Production release 2026-11-08) [Engineering computational software]. KalkuNet. https://kalkunet.com/en/tools/poe-voltage-drop-calculator
@software{kalkunet_poe_voltage_drop_calculator_2026,
author = {{KalkuNet Engineering Team}},
title = {{PoE Cable Voltage Drop Calculator --- KalkuNet Engineering Suite}},
year = {2026},
publisher = {KalkuNet.com},
url = {https://kalkunet.com/en/tools/poe-voltage-drop-calculator},
urldate = {2026-11-08}
}
% LaTeX Engineering Derivation — Generated via https://kalkunet.com/en/tools/poe-voltage-drop-calculator
\begin{equation}
\text{Model: } Total Loop Resistance (Ω) = (Resistance per 100m × Run Length m) ÷ 100
\end{equation}
% Parameter Input Terukur: cableLenM = 65, \; cableType = cat6, \; camPowerWatt = 8, \; sourceVoltage = 48
% Hasil Evaluasi Numerik : cableLenM = \mathbf{65}, \; cableType = \mathbf{cat6}, \; camPowerWatt = \mathbf{8}