Skip to main content
KalkuNet

RAID Calculator: RAID 5, 6, 10 Capacity & IOPS

Usable RAID 0, 1, 5, 6, 10, 50 and 60 capacity in TB and TiB, fault tolerance, write penalty and IOPS.

Calculated in your browserServer & Storage
TB
The figure on the drive label (decimal TB, 10^12 bytes).
See the drive's specification; 0 skips the IOPS part.
%
Usable capacity
16 TB
As the operating system shows it
14.55 TiB
Space efficiency
66.7%
Raw capacity (with spares)
24 TB
Disks that may fail
2 disks
Write penaltydisk operations per random write
6
Maximum random read IOPS
1,200
IOPS at 30% writes
480

Every level for 6 disks × 4 TB

LevelUsable (TB)Efficiency (%)May failWrite penalty
RAID 024100None: one failed disk loses all data1
RAID 1416.75 disks (all but one)2
RAID 52083.31 disk4
RAID 61666.72 disks6
RAID 1012501 disk per mirror pair (up to 3 if in different pairs)2

Formula and sources

Usable: RAID 0 = N × S; RAID 1 = S; RAID 5 = (N − 1) × S; RAID 6 = (N − 2) × S; RAID 10 = N ÷ 2 × S; RAID 50 = (N − G) × S; RAID 60 = (N − 2G) × S TiB = TB × 10^12 ÷ 2^40 (≈ 0.909); hot spares add no capacity Mixed IOPS = N × IOPS per disk ÷ (read share + write share × write penalty); penalty: RAID 0 = 1, RAID 1/10 = 2, RAID 5/50 = 4, RAID 6/60 = 6

When to use the RAID

  • Usable space by level

    RAID 5 gives up one disk to parity, RAID 6 two disks and RAID 10 half the disks to mirroring. Six 4 TB disks leave 16 TB in RAID 6 but only 12 TB in RAID 10. The table under the result compares every level at once.

  • TB on the label, TiB in the system

    Drive makers count 1 TB as 10^12 bytes, while Windows and many NAS systems show TiB (2^40 bytes). That is why 16 TB appears as about 14.55 TiB; nothing has gone missing.

  • Write penalty and IOPS

    Each random write in RAID 5 takes four disk operations (read data, read parity, write data, write parity), in RAID 6 six. Enter the IOPS per disk and the write share to see the array's real IOPS for a mixed workload.

  • RAID 50 and 60

    For large arrays the disks are split into several RAID 5 or RAID 6 groups that are striped together. Fault tolerance applies per group, and a rebuild only involves one group, so it finishes sooner.

Frequently asked questions

RAID 5 or RAID 6 for large disks?

With large drives a rebuild can take hours to days, and during that time RAID 5 has no redundancy left, so many administrators choose RAID 6 or RAID 10.

Do hot spares add capacity?

No. A hot spare sits empty and is taken by the controller to rebuild as soon as a disk fails.

What about ZFS?

ZFS uses RAIDZ and mirrors with its own allocation rules. Use the ZFS calculator for RAIDZ1, RAIDZ2 or RAIDZ3 capacity including its overhead and slop reservation.

Related calculators