Home Power Connection & MCB Calculator
The single- or three-phase PLN connection needed for appliances running at once, with its MCB.
- Need including the margin
- 3,671 VA
- Limiting breaker (MCB)
- 20 A
- Load current
- 13.9 A
- Share of the 2,200 VA connection
- 139%
- Current connection
- not enough; the breaker is likely to trip
PLN single-phase levels
| Power (VA) | MCB (A per phase) | Load (%) | With margin |
|---|---|---|---|
| 450 | 2 | 679.7 | too small |
| 900 | 4 | 339.9 | too small |
| 1,300 | 6 | 235.3 | too small |
| 2,200 | 10 | 139 | too small |
| 3,500 | 16 | 87.4 | too small |
| 4,400 | 20 | 69.5 | enough |
| 5,500 | 25 | 55.6 | enough |
| 7,700 | 35 | 39.7 | enough |
| 11,000 | 50 | 27.8 | enough |
| 13,900 | 63 | 22 | enough |
| 17,600 | 80 | 17.4 | enough |
| 22,000 | 100 | 13.9 | enough |
Formula and sources
Load (VA) = total watts ÷ power factor Need = load × (1 + margin) PLN connection = the smallest level ≥ the need Single-phase current = VA ÷ 220 V; three-phase current per phase = VA ÷ 3 ÷ 220 V MCB = the limiter PLN pairs with that level
When to use the PLN Home Connection & MCB (Indonesia)
Does the breaker keep tripping?
Add up the watts of what was running when the breaker tripped. If the load in VA exceeds your connection, you need to stagger use or ask PLN for more power.
Before buying an air conditioner or induction hob
Add the new appliance to the total and see whether the current connection still fits with a margin. An 1,800 W induction hob, for example, already exceeds a 1,300 VA connection and nearly fills a 2,200 VA one.
Watts are not VA
PLN connections are stated in VA. Appliances with motors or compressors have a power factor below 1, so their VA is higher than the watts on the label.
Connection levels and MCBs
Each PLN level is limited by an MCB of a given rating, such as 10 A for 2,200 VA, or 3 × 16 A for 10,600 VA three phase. The table lists every level with your load as a share of it.
Frequently asked questions
What MCB rating goes with 1,300 VA?
About 6 A, because 1,300 VA ÷ 220 V ≈ 6 A. Likewise 900 VA uses 4 A and 2,200 VA uses 10 A.
Does a bigger connection raise the bill?
The tariff per kWh is the same for 1,300 VA and 2,200 VA, but the postpaid minimum charge rises. A one-off connection fee also applies when upgrading.
When is three phase needed?
It is required for three-phase machines and useful for large loads. A three-phase connection spreads the load over three conductors, so the current per phase is a third of a single-phase connection of the same size.