Skip to main content

TIA-598C Fiber Color Code & RJ45 Pinout Simulator

Visualizer for TIA-598C fiber optic color codes from 1 to 288 cores, tube mapping, and RJ45 LAN pinout diagrams (T568A/T568B) with PoE pairing.

Input Parameters

Try Example:
1288

Calculation Results

Selected Core Number
27
Loose Tube Number
3
Core Position in Tube
3
Tube Color (TIA-598C)
Tube #3: Hijau (Green) (Solid)
Fiber / Core Color (TIA-598C)
Core #3 (di dalam Tube): Hijau (Green) (Solid)
Tube Hex Color Code
#16a34a
Core Hex Color Code
#16a34a
Total Tube Count in Cable
4
Selected RJ45 Wiring Standard
T568B
Want to compare 2 design options side-by-side (e.g., Scenario A vs Scenario B)?
⚡ Network Reflex Speed Drill (SKKNI, MTCNA & CCNA)
Test MTCNA / CCNA skills & download stamped score certificate
⚡ Enterprise Network Infrastructure Standard
Managed L2+/L3 Gigabit Switch (802.1Q VLAN & RSTP) + Cat6/FO Uplink
RFC 1918 / RFC 4632 Compliant Addressing

Isolate management, server, user, and IoT/CCTV traffic into dedicated 802.1Q VLANs.

12-Core Sequence Table in Selected Tube
Global Core NumberPosition in TubeHex Color Code
Core #25Pin/Core 1#2563eb
Core #26Pin/Core 2#f97316
Core #27Pin/Core 3#16a34a
Core #28Pin/Core 4#78350f
Core #29Pin/Core 5#64748b
Core #30Pin/Core 6#f8fafc
Core #31Pin/Core 7#dc2626
Core #32Pin/Core 8#0f172a
Core #33Pin/Core 9#eab308
Core #34Pin/Core 10#7c3aed
Core #35Pin/Core 11#ec4899
Core #36Pin/Core 12#06b6d4
RJ45 LAN Pinout Table & PoE Pin Mapping
RJ45 Pin NumberEthernet Signal FunctionPoE Power Allocation
Pin 1BI_DA+ (TX+)DC+ (PoE Mode A)
Pin 2BI_DA- (TX-)DC+ (PoE Mode A)
Pin 3BI_DB+ (RX+)DC- (PoE Mode A)
Pin 4BI_DC+ (Gigabit)DC+ (PoE Mode B)
Pin 5BI_DC- (Gigabit)DC+ (PoE Mode B)
Pin 6BI_DB- (RX-)DC- (PoE Mode A)
Pin 7BI_DD+ (Gigabit)DC- (PoE Mode B)
Pin 8BI_DD- (Gigabit)DC- (PoE Mode B)

🔬Fiber Loose-Tube Cross-Section & RJ45 Pinout Visualizer

TIA-598C / TIA-568-T568B
Penampang Tube #3
JELLY123456789101112

Active selected core: #3 (Core #3 (di dalam Tube): Hijau (Green) (Solid))

RJ45 Connector — T568B Standard
12345678

Pinout order: 1 (White/Orange) to 8 (Brown) — Gigabit & PoE Ready

Share to WhatsApp
ℹ️

Technical Accuracy Note: Calculation results are engineering estimates based on standard RFC/IEEE/ITU-T models. Actual field performance may vary due to protocol overhead, hardware specifications, and environmental factors.

🚀 Share Calculation Results or Embed on Your Site

Deep-link automatically preserves your current inputs — ideal for WhatsApp, Telegram, Reddit, or engineering docs.

How to Use This Tool

  1. Enter your target optical fiber core number (1 to 288 cores) and select your cable's core density per loose tube (6, 12, or 24 cores).
  2. Choose your preferred copper RJ45 wiring standard (commercial standard T568B, residential T568A, or Ethernet Crossover).
  3. Inspect the interactive loose-tube cross-section SVG, identify the exact fiber and tube color pairings, and review the 8-pin RJ45 pinout and PoE power table.

Worked Example: Tracing Core #27 on 48-Core Trunk Cable & T568B Pinout

Computed example: Core number 27 within a 48-core cable (12 cores/tube) resides inside Tube #3 (Solid Green) at core position #3 (Green). For T568B LAN cabling, Pins 1-2 utilize the White-Orange/Orange pair providing PoE Mode A positive DC voltage.

Example Input
Target Core Number to Trace (1–288)
27
Cores Count per Loose Tube
12 Cores per Tube (Industry Standard)
Total Cable Core Capacity
48 Cores (4 Tubes)
RJ45 Pinout Wiring Standard
T568B (Commercial / Standard)
Calculated Output
Selected Core Number
27
Loose Tube Number
3
Core Position in Tube
3
Tube Color (TIA-598C)
Tube #3: Hijau (Green) (Solid)
Fiber / Core Color (TIA-598C)
Core #3 (di dalam Tube): Hijau (Green) (Solid)
Tube Hex Color Code
#16a34a
Core Hex Color Code
#16a34a
Total Tube Count in Cable
4
Selected RJ45 Wiring Standard
T568B
12-Core Sequence Table in Selected Tube
Global Core NumberPosition in TubeHex Color Code
Core #25Pin/Core 1#2563eb
Core #26Pin/Core 2#f97316
Core #27Pin/Core 3#16a34a
Core #28Pin/Core 4#78350f
Core #29Pin/Core 5#64748b
Core #30Pin/Core 6#f8fafc
Core #31Pin/Core 7#dc2626
Core #32Pin/Core 8#0f172a
Core #33Pin/Core 9#eab308
Core #34Pin/Core 10#7c3aed
Core #35Pin/Core 11#ec4899
Core #36Pin/Core 12#06b6d4
RJ45 LAN Pinout Table & PoE Pin Mapping
RJ45 Pin NumberEthernet Signal FunctionPoE Power Allocation
Pin 1BI_DA+ (TX+)DC+ (PoE Mode A)
Pin 2BI_DA- (TX-)DC+ (PoE Mode A)
Pin 3BI_DB+ (RX+)DC- (PoE Mode A)
Pin 4BI_DC+ (Gigabit)DC+ (PoE Mode B)
Pin 5BI_DC- (Gigabit)DC+ (PoE Mode B)
Pin 6BI_DB- (RX-)DC- (PoE Mode A)
Pin 7BI_DD+ (Gigabit)DC- (PoE Mode B)
Pin 8BI_DD- (Gigabit)DC- (PoE Mode B)

Core Concept & Engineering Notes

Standardized color coding across optical fiber infrastructures and twisted-pair copper Ethernet cabling (RJ45) underpins the structural integrity of modern enterprise data networks and telecommunications. Precise wire mapping is paramount during field fusion splicing, optical patch bay terminations, and high-wattage Power over Ethernet (PoE) hardware deployments. For multi-fiber loose-tube cables, the global telecommunications sector adheres to the ANSI/TIA-598-C and TIA-598-D specifications. This standard governs a standardized 12-color sequence for optical fibers: 1-Blue, 2-Orange, 3-Green, 4-Brown, 5-Slate (Gray), 6-White, 7-Red, 8-Black, 9-Yellow, 10-Violet, 11-Rose (Pink), and 12-Aqua. High-strand-count trunk cables (24, 48, 96, 144, up to 288 cores) group glass fibers into color-coded plastic loose tubes that replicate the identical 12-color progression. For installations exceeding 144 cores, subsequent buffer tubes incorporate black tracer stripes or intermittent ring markings to prevent transposition errors during splicing. In structured copper Ethernet cabling (Cat5e, Cat6, Cat6A), ANSI/TIA-568.2-D governs the two pinout wiring standards: T568A and T568B. T568B represents the dominant commercial wiring topology deployed across data centers and corporate campuses, following the sequence: 1-White/Orange, 2-Orange, 3-White/Green, 4-Blue, 5-White/Blue, 6-Green, 7-White/Brown, and 8-Brown. Accurate pair alignment is mandatory for Power over Ethernet (IEEE 802.3af/at/bt) compliance: PoE Mode A delivers DC power concurrently over data pairs 1-2 (positive) and 3-6 (negative), whereas PoE Mode B transmits power over spare pairs 4-5 (positive) and 7-8 (negative). Wiring mismatches degrade differential pair cancellation, elevate near-end crosstalk (NEXT), and can cause hardware damage on active PoE ports.

How It Was Calculated (Formulas & Steps)

Frequently Asked Questions (FAQ)

What is the practical difference between T568A and T568B LAN cabling?

Electrically and in data throughput, both standards perform identically. The distinction lies in swapping the positions of the Orange pair (Pins 1-2 on T568B) and Green pair (Pins 1-2 on T568A). T568B is the universal commercial standard.

How do you determine fiber color codes for core numbers above 12?

Apply division arithmetic: Buffer Tube Number = Ceil(Core / Cores Per Tube). Relative Core Position in Tube = (Core - 1) MOD Cores Per Tube + 1. Every individual buffer tube replicates the identical 12-color TIA-598 sequence.

What is the difference between PoE Mode A and PoE Mode B on RJ45 cables?

PoE Mode A (Endspan) delivers DC electrical power simultaneously over active data pairs on Pins 1, 2, 3, and 6. PoE Mode B (Midspan) delivers DC voltage exclusively over spare conductor pairs on Pins 4, 5 (positive) and 7, 8 (negative).

Why does a straight-through T568B cable work when connecting two modern switches?

Modern network interfaces incorporate automated Auto MDI/MDI-X switching logic. Hardware PHY chips automatically detect transmit and receive polarities and invert TX/RX differential lines internally without requiring crossover cables.

🔗Related Scenarios & Companion Calculators

Browse All 30+ Scenarios →
🔬 Scientific Methodology & Normative Verification

Engineering Sensitivity Analysis, Response Curve & Technical Citation

✓ Calibrated to ISO/IEC/IEEE/TIA Clauses

1. 1. 3-Point Engineering Sensitivity & Tolerance Envelope

Comparative evaluation across theoretical laboratory bounds (0% loss), current nominal operating point, and conservative field safety bounds (±15% thermal/aging derating).

Evaluated Parameter Ideal Theoretical Bound Nominal Operating Point Conservative Safety Bound (±15%) Engineering Derating Rule
Selected Core Number 24.3 27 31.05 Engineering Safety Margin (+15% Overhead)
Loose Tube Number 2.7 3 3.45 Engineering Safety Margin (+15% Overhead)
Core Position in Tube 2.7 3 3.45 Engineering Safety Margin (+15% Overhead)
Total Tube Count in Cable 3.6 4 4.6 Engineering Safety Margin (+15% Overhead)

2. 2. Mathematical Function Curve & Operating Coordinate (x₀, y₀)

MATHEMATICAL RESPONSE CURVE: SELECTED CORE NUMBER VS TARGET CORE NUMBER Conservative Engineering Bound (+15% Safety Margin) 10.8 16.2 21.6 27 32.4 37.8 43.2 (x₀=27, y₀=27) Variabel Independen (x): Target Core Number

3. 3. Physical Constants & Normative Standard Clauses

R_loop(Cat6, 20°C) = 14 Ω/100m ANSI/TIA-568.2-D & IEEE 802.3bt

DC Loop Resistance for 23 AWG Solid Copper Cat6

Clause 6.4.1 / Table 145-1 — Nominal 23 AWG solid copper loop resistance at 20°C is 14.0 Ω/100m (TIA maximum ceiling is 18.8 Ω/100m).

α_opt(1490nm) = 0.25 dB/km ITU-T Rec. G.652.D & G.984.2

Single-Mode Optical Fiber Attenuation Coefficient at 1490 nm

Table 1 / Class B+ & C+ Optical Path — Typical G.652.D attenuation at 1490 nm downstream is 0.22–0.25 dB/km (1310 nm upstream: 0.35 dB/km).

α_Cu(20°C) = 0.00393 °C⁻¹ IEC 60028

Temperature Coefficient of Resistance for Copper

International Annealed Copper Standard — Used in thermal derating equation: R(T) = R_20 × [1 + 0.00393 × (T - 20)].

4. 4. Independent Technical & Academic Citation (IEEE / APA 7th / BibTeX / LaTeX)

Use the standard citation formats below to reference this computational methodology in engineering specifications, audit reports, or academic papers.

Format IEEE & APA 7th Edition

[IEEE] KalkuNet Engineering Team, "TIA-598C Fiber Color Code & RJ45 Pinout Simulator — Standard Engineering Computational Instrument," KalkuNet Technical Suite, 2026. [Online]. Available: https://kalkunet.com/en/tools/fiber-color-code-rj45-simulator. [Accessed: 2026-11-08].

[APA 7th] KalkuNet Engineering Team. (2026). TIA-598C Fiber Color Code & RJ45 Pinout Simulator (Production release 2026-11-08) [Engineering computational software]. KalkuNet. https://kalkunet.com/en/tools/fiber-color-code-rj45-simulator

BibTeX & LaTeX Derivation Snippet
@software{kalkunet_fiber_color_code_rj45_simulator_2026,
  author = {{KalkuNet Engineering Team}},
  title = {{TIA-598C Fiber Color Code & RJ45 Pinout Simulator --- KalkuNet Engineering Suite}},
  year = {2026},
  publisher = {KalkuNet.com},
  url = {https://kalkunet.com/en/tools/fiber-color-code-rj45-simulator},
  urldate = {2026-11-08}
}

% LaTeX Engineering Derivation — Generated via https://kalkunet.com/en/tools/fiber-color-code-rj45-simulator
\begin{equation}
  \text{Model: } Buffer Tube Number = ceil(Core Number ÷ Cores per Tube)
\end{equation}
% Parameter Input Terukur: targetCoreNumber = 27, \; coresPerTube = 12, \; totalCableCores = 48, \; rj45Standard = T568B
% Hasil Evaluasi Numerik : selectedCoreNumber = \mathbf{27}, \; tubeNumber = \mathbf{3}, \; corePositionInTube = \mathbf{3}